ABCD3TA epi

A barrel kapton hybrid with 12 "new epi" ABCD3TA  chips was irradiated in the
reactor in Ljubljana in September 2001

The same setup was used as for the previous irradiation.

Results:

Trim DACs and thresholds spread:

No range setting problems observed after irradiation. Trim DAC curves for all chips and
all ranges before and after irradiation.

The distribution of 50% points for all channels after trimming is shown here.
Evolution of spread of 50% point with received fluence can be seen in this plot. The chips were trimmed
(with 1fC pulse at Ipreamp=150 Ishaper=20) only before irradiation and then the same trim DAC values were used for all measurements in this plot.
 

Response curve:

Response curve is shown here.

Time walk:

Time walk.

Gain and Noise:

Gain and noise was measured from threshold scans done with 4 charges , 1, 2, 3 and 4 fC
at shaper currents 20 and 30uA and preamp currents 100, 150, 200 and 250uA.

Here is the gain and noise evolution at Ipreamp = 100uA and Ishaper = 20uA.
Gain and noise across the hybrid at  Ipreamp = 100uA and Ishaper = 20uA.
 

Conclusions:

All chips were fully functional after irradiation.
Noise increased from 500 ENC before irradiation to 1000 ENC after irradiation (at
Ipreamp = 100uA and Ishaper = 20uA). This is for about  200 electrons more than
after irradiation with 3e14 protons/cm2 at PS (1.8e14 NIEL neutrons/cm2). But
this seems to be consistent with previous irradiation where about the same difference
in noise increase was seen after irradiation at PS and Ljubljana reactor.