-- $HeadURL: http://svn.wiener-d.com/src/enet/trunk/mibs/WIENER-CRATE-MIB.txt $
-- $LastChangedDate: 2007-04-23 10:51:38 +0200 (Mo, 23 Apr 2007) $                                                                            
-- $LastChangedRevision: 195 $                                                                        
-- $LastChangedBy: koester $                                                                              
-- Copyright  2005-2007 W-IE-NE-R Plein & Baus GmbH, Burscheid, Germany                            
----------------------------------------------------------------------------------------------------
WIENER-CRATE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY,
    Integer32, Opaque, enterprises, Counter32
        FROM SNMPv2-SMI

    TEXTUAL-CONVENTION, DisplayString, TruthValue
	FROM SNMPv2-TC
	
--    Float
--	    FROM NET-SNMP-TC
--    Float 
--	    FROM UCD-SNMP-MIB
	;


--
-- Define the Float Textual Convention
--   This definition was written by David Perkins.
--

Float ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "A single precision floating-point number.  The semantics
         and encoding are identical for type 'single' defined in
         IEEE Standard for Binary Floating-Point,
         ANSI/IEEE Std 754-1985.
         The value is restricted to the BER serialization of
         the following ASN.1 type:
             FLOATTYPE ::= [120] IMPLICIT FloatType
         (note: the value 120 is the sum of '30'h and '48'h)
         The BER serialization of the length for values of
         this type must use the definite length, short
         encoding form.

         For example, the BER serialization of value 123
         of type FLOATTYPE is '9f780442f60000'h.  (The tag
         is '9f78'h; the length is '04'h; and the value is
         '42f60000'h.) The BER serialization of value
         '9f780442f60000'h of data type Opaque is
         '44079f780442f60000'h. (The tag is '44'h; the length
         is '07'h; and the value is '9f780442f60000'h."
    SYNTAX Opaque (SIZE (7))



wiener MODULE-IDENTITY


    LAST-UPDATED "200703160000Z"
    ORGANIZATION "WIENER Plein & Baus GmbH"
    CONTACT-INFO "
         postal:   WIENER Plein & Baus GmbH
                   Mullersbaum 20
                   D-51399 Burscheid
                   Germany

         email:    info@wiener-d.com

        "
    DESCRIPTION
	"This revision introduces new OIDs for slew control:
	  outputVoltageRiseRate and outputVoltageFallRate.
	"

    REVISION "200502010000Z"
    DESCRIPTION
	"This revision introduces new OIDs for group managment:
      groupTable	  
	"

    REVISION "200406280000Z"
    DESCRIPTION
	"WIENER Crate MIB, actual Firmware: UEL6E 4.02.
	 Initial Version.
	"

    ::= { enterprises 19947 }


-------------------------------------------------------------------------------
-- crate
-------------------------------------------------------------------------------

crate       OBJECT-TYPE
    SYNTAX  Crate
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "SNMP control for electronic crates. A crate is a complete electronic system and 
			consists of the mechanical rack, a power supply, a fan tray and a backplane.
			All this things are necessary to provide an adequate housing for electronic
			modules (e.g. VME CPU's)"
    ::= { wiener 1 }


Crate ::= SEQUENCE {
        system
            System,
		input
		    Input,
		output
		    Output,
		sensor
		    Sensor,
    communication
		    Communication,
		powersupply
		    Powersupply,
		fantray
		    Fantray,
		rack
		    Rack
}

system      OBJECT-TYPE
    SYNTAX  System
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A collection of objects which affect the complete crate"
    ::= { crate 1 }


input       OBJECT-TYPE 
    SYNTAX  Input
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are associated with the power input of the crate"
    ::= { crate 2 }

output      OBJECT-TYPE 
    SYNTAX  Output
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are associated with the power output of the crate"
    ::= { crate 3 }

sensor      OBJECT-TYPE 
    SYNTAX  Sensor
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are associated with temperature sensors in the crate"
    ::= { crate 4 }

communication OBJECT-TYPE 
    SYNTAX  Communication
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which affect the remote control of the crate"
    ::= { crate 5 }

powersupply OBJECT-TYPE 
    SYNTAX  Powersupply
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are specific for the power supply of the crate"
    ::= { crate 6 }

fantray     OBJECT-TYPE 
    SYNTAX  Fantray
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are specific for the fan tray of the crate"
    ::= { crate 7 }

rack        OBJECT-TYPE 
    SYNTAX  Rack
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "All objects which are specific for the crate (BIN) of the crate"
    ::= { crate 8 }


-------------------------------------------------------------------------------
-- system
-------------------------------------------------------------------------------
System ::= SEQUENCE {
        sysMainSwitch
            INTEGER,
		sysStatus
		    BITS,
		sysVmeSysReset
		    INTEGER
}

sysMainSwitch OBJECT-TYPE
    SYNTAX  INTEGER { OFF (0), ON (1) }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Read: An enumerated value which shows the current state of
			 the crates main switch.
             Write: Try to switch the complete crate ON or OFF.
			 Only the values ON or OFF are allowed."
    ::= { system 1 }

sysStatus OBJECT-TYPE
    SYNTAX  BITS {
        mainOn (0) ,
        mainInhibit (1) ,
        localControlOnly (2) ,
        inputFailure (3) ,
        outputFailure (4) ,
        fantrayFailure (5) ,
        sensorFailure (6),
        VmeSysfail (7),
        plugAndPlayIncompatible (8)
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "A bit string which shows the status (health) of the complete crate.
             If a bit is set (1), the explanation is satisfied
                mainOn (0),					system is switched on, individual outputs may be controlled by their specific ON/INHIBIT
                mainInhibit(1),				external (hardware-)inhibit of the complete system
                localControlOnly (2),		local control only (CANBUS write access denied)
                inputFailure (3),			any input failure (e.g. power fail)
                outputFailure (4),			any output failure, details in outputTable
                fantrayFailure (5),			fantray failure
        		sensorFailure (6),     		temperature of the external sensors too high
        		VmeSysfail(7),				VME SYSFAIL signal is active
        		plugAndPlayIncompatible (8)	wrong power supply and rack connected
        	"
    ::= { system 2 }


--        ERROR_BIN_CHECKSUM(?), 





sysVmeSysReset OBJECT-TYPE
    SYNTAX  INTEGER { TRIGGER (1) }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Read: Always 0.
             Write: Trigger the generation of the VME SYSRESET signal.
			 This signal will be active for a time of 200 ms"
    ::= { system 3 }


-------------------------------------------------------------------------------
-- input
-------------------------------------------------------------------------------
-- reserved, possible entries:
--   inputSetPfcVoltage
--   inputMesPowerFail
--   inputMesVoltage
--   inputMesCurrent
--   inputMesPower
--   inputMesTemperature
-------------------------------------------------------------------------------
-- output
-------------------------------------------------------------------------------
Output ::= SEQUENCE {
        outputNumber
		    INTEGER,
        outputTable
            OutputTable
        groupsNumber
		    INTEGER,
        groupsTable
            GroupsTable

--TotalPower

}



outputNumber OBJECT-TYPE
    SYNTAX  INTEGER (0..255)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The number of output channels of the crate."
    ::= { output 1 }

outputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF outputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of output entries."
    ::= { output 2 }

groupsNumber OBJECT-TYPE
    SYNTAX  INTEGER (1..255)
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The number of output groups of the crate."
    ::= { output 3 }

groupsTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF groupsEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of output groups entries."
    ::= { output 4 }

outputEntry OBJECT-TYPE
    SYNTAX  outputEntry
    MAX-ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "A table row"
    INDEX   { outputIndex }
    ::= { outputTable 1 }

OutputEntry ::=
    SEQUENCE {
        outputChannel
            INTEGER,
        outputName
            DisplayString,
        outputGroup
            INTEGER,

        outputStatus
		    BITS,
        outputMeasurementSenseVoltage
		    Float,
        outputMeasurementTerminalVoltage
		    Float,
        outputMeasurementCurrent
		    Float,
        outputMeasurementTemperature
		    INTEGER,


        outputSwitch
		    INTEGER,
        outputVoltage
		    Float,
        outputAdjustVoltage
		    INTEGER,
        outputCurrent
		    Float,

        outputVoltageRiseRate
		    Float,
        outputVoltageFallRate
		    Float,

        outputSupervisionBehavior
            INTEGER,
        outputSupervisionMinSenseVoltage
		    Float,
        outputSupervisionMaxSenseVoltage
		    Float,
        outputSupervisionMaxTerminalVoltage
		    Float,
        outputSupervisionMaxCurrent
		    Float,
        outputSupervisionMaxTemperature
		    INTEGER,

        outputConfigMaxSenseVoltage
		    Float,
        outputConfigMaxTerminalVoltage
		    Float,
        outputConfigMaxCurrent
		    Float,
        outputSupervisionMaxPower
		    Float,



    }


outputIndex OBJECT-TYPE
    SYNTAX  INTEGER { U0(1), U1(2), U2(3), U3(4), U4(5), U5(6), U6(7), U7(8), U8(9), U9(10), U10(11), U11(12), 101, 102 }
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A unique number for each power output channel. Its value
            ranges between 1 and total number of output channels.
			This value is equivalent to the output channel number at
			the type label of the crate or power supply, but because the SMI
			index starts at 1, index 1 corresponds to U0."
    ::= { outputEntry 1 }

outputName OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (1..4))
    ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "A textual string containing a short name of the
            output. If the crate is equipped with an alphanumeric
			display, this string is shown to identify a output channel."
    ::= { outputEntry 2 }

outputGroup OBJECT-TYPE
    SYNTAX  INTEGER (0..127)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The group number associated with this channel"
    ::= { outputEntry 3 }


outputStatus OBJECT-TYPE
    SYNTAX  BITS {
        outputOn (0) ,
        outputInhibit (1) ,
        outputFailureMinSenseVoltage (2),
        outputFailureMaxSenseVoltage (3),
        outputFailureMaxTerminalVoltage (4),
        outputFailureMaxCurrent (5),
        outputFailureMaxTemperature (6),
        outputFailureMaxPower (7),
        -- reserved
        outputFailureTimeout (9),
   		outputCurrentLimited (10),
   		outputRampUp (11),
   		outputRampDown (12),
    }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "A bit string which shows the status (health and operating conditions) of one output channel.
             If a bit is set (1), the explanation is satisfied:
                outputOn (0),							output channel is on
                outputInhibit(1),						external (hardware-)inhibit of the output channel
        		outputFailureMinSenseVoltage (2)		Supervision limit hurt: Sense voltage is too low
        		outputFailureMaxSenseVoltage (3),		Supervision limit hurt: Sense voltage is too high
        		outputFailureMaxTerminalVoltage (4),	Supervision limit hurt: Terminal voltage is too high
        		outputFailureMaxCurrent (5),			Supervision limit hurt: Current is too high
        		outputFailureMaxTemperature (6),		Supervision limit hurt: Heat sink temperature is too high
        		outputFailureMaxPower (7),				Supervision limit hurt: Output power is too high
                outputFailureTimeout (9),				Communication timeout between output channel and main control
		   		outputCurrentLimited (10),				Current limiting is active (constant current mode)
   				outputRampUp (11),						Output voltage is increasing (e.g. after switch on)
   				outputRampDown (12),					Output voltage is decreasing (e.g. after switch off)

        	"

    ::= { outputEntry 4 }




outputMeasurementSenseVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The measured voltage at the sense input lines."
    ::= { outputEntry 5 }

outputMeasurementTerminalVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-only
    STATUS  optional
    DESCRIPTION
            "The measured voltage at the output terminals."
    ::= { outputEntry 6 }

outputMeasurementCurrent OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The measured output current."
    ::= { outputEntry 7 }

outputMeasurementTemperature OBJECT-TYPE
    SYNTAX  INTEGER { OK (-128), FAILURE(127) }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The measured temperature of the power module."
    ::= { outputEntry 8 }


outputSwitch OBJECT-TYPE
    SYNTAX  INTEGER { OFF (0), ON (1) }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Read: An enumerated value which shows the current state of
			 the output channel.
             Write: Change the state of the channel.
             If the channel is on, and the write value is OFF, then the channel
             will switch off.
             If the channel is off, and the write value is ON, and if no other
             signals (mainInhibit or outputInhibit) are active, then the channel
             will switch on.
			 Only the values ON or OFF are allowed."
    ::= { outputEntry 9 }

outputVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The nominal output voltage of the channel."
    ::= { outputEntry 10 }

outputAdjustVoltage OBJECT-TYPE
    SYNTAX  INTEGER (-128..127)
    ACCESS  read-write
    STATUS  obsolete
    DESCRIPTION
            "A posibillity to make small changes of the output voltage."
    ::= { outputEntry 11 }

outputCurrent OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The current limit of the channel."
    ::= { outputEntry 12 }

outputVoltageRiseRate OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Voltage Fall Slew Rate [V/s].
			 The slew rate of the output voltage if it increases (after switch on or if the Voltage has been
			 changed).
		    "
    ::= { outputEntry 13 }

outputVoltageFallRate OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Voltage Rise Slew Rate [V/s].
			 The slew rate of the output voltage if it decreases (after switch off or if the Voltage has been
			 changed).
		    "
    ::= { outputEntry 14 }

outputSupervisionBehavior OBJECT-TYPE
-- CHECK    SYNTAX  INTEGER { Ignore (0), (1..1022), SwitchOffCrate (1023) }
    SYNTAX  INTEGER (0..65535)
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "A bit field packed into an integer which define the behavior of the output channel / power supply
             after failures.
             For each supervision value, a two-bit field exists.
             The enumeration of this value (..L+..H*2) is:
              	0			ignore the failure
              	1			switch off this channel
              	2			switch off all channels with the same group number
              	3			switch off the complete crate.
             The position of the bit fields in the integer value are:
        		Bit 0, 1:	outputFailureMinSenseVoltage
        		Bit 2, 3:	outputFailureMaxSenseVoltage
        		Bit 4, 5:	outputFailureMaxTerminalVoltage
        		Bit 6, 7:	outputFailureMaxCurrent
        		Bit 8, 9:	outputFailureMaxTemperature
        		Bit 10, 11:	outputFailureMaxPower
        		Bit 12, 13:	reserved
        		Bit 14, 15:	outputFailureTimeout
        	"

    ::= { outputEntry 15 }

outputSupervisionMinSenseVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured sense voltage is below this value, the power supply
			 performs the function defined by SupervisionAction."
    ::= { outputEntry 16 }

outputSupervisionMaxSenseVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured sense voltage is above this value, the power supply
			 performs the function defined by SupervisionAction."
    ::= { outputEntry 17 }

outputSupervisionMaxTerminalVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured voltage at the power supply output
			 terminals is above this value, the power supply
			 performs the function defined by SupervisionAction."
    ::= { outputEntry 18 }

outputSupervisionMaxCurrent OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured current is above this value, the power supply
			 performs the function defined by SupervisionAction."
    ::= { outputEntry 19 }

--outputSupervisionMaxTemperature OBJECT-TYPE  wohl besser config !!
--    SYNTAX  INTEGER
--    ACCESS  read-write
--    STATUS  current
--    DESCRIPTION
--            "If the measured module temperature is above this value, the power supply
--			 performs the function defined by SupervisionAction."
--    ::= { outputEntry 20 }



outputConfigMaxSenseVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The maximum possible value of the sense voltage"
    ::= { outputEntry 21 }

outputConfigMaxTerminalVoltage OBJECT-TYPE
    SYNTAX  Float
    UNITS   "V"
    ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The maximum possible value of the terminal voltage"
    ::= { outputEntry 22 }

outputConfigMaxCurrent OBJECT-TYPE
    SYNTAX  Float
    UNITS   "A"
    ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The maximum possible value of the output current"
    ::= { outputEntry 23 }

outputSupervisionMaxPower OBJECT-TYPE
    SYNTAX  Float
    UNITS   "W"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured power (measured current * measured terminal voltage) 
             is above this value, the power supply performs the function defined
              by SupervisionAction."
    ::= { outputEntry 24 }

-------------------------------------------------------------------------------
-- output->groups
-------------------------------------------------------------------------------

groupsEntry OBJECT-TYPE
    SYNTAX  groupsEntry
    MAX-ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
            "A table row"
    INDEX   { groupsIndex }
    ::= { groupsTable 1 }

GroupsEntry ::=
    SEQUENCE {
        groupsIndex
            INTEGER,
--      outputGroupsName
--            DisplayString,
--        outputGroupsGroup
--            INTEGER,

--        outputGroupsStatus
--		    BITS,
--        outputGroupsMeasurementSenseVoltage
--		    Float,
--        outputMeasurementTerminalVoltage
--		    Float,
--        outputMeasurementCurrent
--		    Float,
--        outputMeasurementTemperature
--		    INTEGER,


        groupsSwitch
		    INTEGER,
--        outputVoltage
--		    Float,
--        outputAdjustVoltage
--		    INTEGER,
--        outputCurrent
--		    Float,

--        outputRampUp
--		    Float,
--        outputRampDown
--		    Float,

--        outputSupervisionBehavior
--            INTEGER,
--        outputSupervisionMinSenseVoltage
--		    Float,
--        outputSupervisionMaxSenseVoltage
--		    Float,
--        outputSupervisionMaxTerminalVoltage
--		    Float,
--        outputSupervisionMaxCurrent
--		    Float,
--        outputSupervisionMaxTemperature
--		    INTEGER,

--        outputConfigMaxSenseVoltage
--		    Float,
--        outputConfigMaxTerminalVoltage
--		    Float,
--        outputConfigMaxCurrent
--		    Float,
--        outputSupervisionMaxPower
--		    Float,
    }

groupsIndex OBJECT-TYPE
    SYNTAX  INTEGER { ALL(0), (1..126) }
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A unique number for each power output group. Its value
             ranges between 1 and 126.
             The special group 0 is predefined and gives access to all channels.
            "
    ::= { groupsEntry 1 }

groupsSwitch OBJECT-TYPE
    SYNTAX  INTEGER { UNDEFINED (-1), OFF (0), ON (1) }
    MAX-ACCESS  write-only
    STATUS  current
    DESCRIPTION
            "Read: This function is not defined with groups of output channels.
             Write: Switch all channels of a group on or off.
             If any channel is on, and the write value is OFF, then all channels
             will switch off.
             If any channel is off, and the write value is ON, and if no other
             signals (mainInhibit or outputInhibit) are active, then all channels
             will switch on.
			 Only the values ON or OFF are allowed."
    ::= { groupsEntry 9 }

--groupsName OBJECT-TYPE
--    SYNTAX  DisplayString (SIZE (1..4))
--    ACCESS  read-only
--    STATUS  current
--    DESCRIPTION
--            "A textual string containing a short name of the
--            output. If the crate is equipped with an alphanumeric
--			display, this string is shown to identify a output channel."
--    ::= { groupsEntry 2 }




-------------------------------------------------------------------------------
-- sensor
-------------------------------------------------------------------------------
Sensor ::= SEQUENCE {
        sensorNumber
		    INTEGER,
        sensorTable
            SensorTable
}

sensorNumber OBJECT-TYPE
    SYNTAX  INTEGER (0..8)
    ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The number of temperature sensors of the crate."
    ::= { sensor 1 }

sensorTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF sensorEntry
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
           "A list of sensor entries."
    ::= { sensor 2 }

sensorEntry OBJECT-TYPE
    SYNTAX  SensorEntry
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "An output entry containing objects at the
            interface."
    INDEX   { sensorIndex }
    ::= { sensorTable 1 }

SensorEntry ::=
    SEQUENCE {
        sensorIndex
            INTEGER,
        sensorTemperature
            INTEGER
        sensorWarningThreshold
            INTEGER
        sensorFailureThreshold
            INTEGER
    }

sensorIndex OBJECT-TYPE
    SYNTAX  INTEGER { TEMP1 (1), TEMP2(2), TEMP3(3), TEMP4(4), TEMP5(5),
	  TEMP6(6), TEMP7(7), TEMP8(8) }
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A unique number for each temperature sensor in the crate"
    ::= { sensorEntry 1 }

sensorTemperature OBJECT-TYPE
-- CHECK    SYNTAX  INTEGER { UNUSED(-128), (-127..127) }
    SYNTAX  INTEGER (-128..127)
    UNITS   "C"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The measured temperature of the sensor.
			 Unused temperature probes have the special value -128"
    ::= { sensorEntry 2 }

sensorWarningThreshold OBJECT-TYPE 
-- CHECK    SYNTAX  INTEGER  { (0..126), DISABLED(127) }
    SYNTAX  INTEGER  (0..127)
    UNITS   "C"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured temperature of the sensor is higher than this
			value, the fan speed of the connected fan tray is increased.
			The value 127 has the special meaning: channel disabled."
    ::= { sensorEntry 3}

sensorFailureThreshold OBJECT-TYPE
-- CHECK    SYNTAX  INTEGER  { (0..126), DISABLED(127) }
    SYNTAX  INTEGER  (0..127)
    UNITS   "C"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "If the measured temperature of the sensor is higher than this
			value, the power supply switches off.
			The value 127 has the special meaning: channel disabled."
    ::= { sensorEntry 4}



-------------------------------------------------------------------------------
-- communication
-------------------------------------------------------------------------------
Communication ::= SEQUENCE {
        snmp
		    Snmp,
        tcpip
            Tcpip,
        http
            Http,
        telnet
            Telnet,
        canbus
            Canbus,
        rs232
            RS232
}

-------------------------------------------------------------------------------
-- communication.snmp
-------------------------------------------------------------------------------
snmp OBJECT-TYPE
    SYNTAX  Snmp
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "SNMP configuration."
    ::= { communication 1 }

Snmp ::= SEQUENCE {
        snmpCommunityTable
            SnmpCommunityTable
        snmpPort
		    INTEGER,
}

snmpCommunityTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF SnmpCommunityEntry
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
           "The SNMP community string table for different views."
    ::= { snmp 1 }

snmpCommunityEntry OBJECT-TYPE
    SYNTAX  SnmpCommunityEntry
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "One table row."
    INDEX   { snmpAccessRight }
    ::= { snmpCommunityTable 1 }


SnmpEntry ::= SEQUENCE {
        snmpAccessRight
		    INTEGER,
        snmpCommunityName
            OCTET STRING
}

snmpAccessRight OBJECT-TYPE
    SYNTAX  INTEGER { public (1), private (2), admin (3), guru (4) }
    ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A unique number for each access right"
    ::= { snmpCommunityEntry 1 }

snmpCommunityName OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (0..14))
    ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The SNMP community names for different views. The rights of the different communities are:
               public       no write access
               private      can switch power on/off, generate system reset
               admin        can change supervision levels
               guru         can change output voltage & current (this may destroy hardware if done wrong!)
             Setting a community name to a zero-length string completly
             disables the access to this view. If there is no higher-
             privileged community, the community name can only changed
             by direct access to the crate (not via network)!
            "
    ::= { snmpCommunityEntry 2}

snmpPort OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The UDP port number of the SNMP protocol"
    ::= { snmp 2}

-------------------------------------------------------------------------------
-- communication....
-------------------------------------------------------------------------------

-- other future entries:
-- +-tcpip
-- | |
-- | +- tcpipIpAddress
-- | +- tcpipGateway
-- | +- tcpipSubnetMask
-- | +- tcpipNegotiation
-- | +- tcpipMAC
-- |
-- +-http
-- | |
-- | +- httpPort
-- | +- httpWriteEnable
-- |
-- +-telnet
-- | |
-- | +- telnetPort
-- |
-- +-canbus
-- | |
-- | +- address
-- | +- address2
-- | +- speed
-- |
-- +-rs232
-- | |
-- | +- ?



-------------------------------------------------------------------------------
-- powersupply
-------------------------------------------------------------------------------
Powersupply ::= SEQUENCE {
        psFirmwareVersion
            DisplayString,
        psSerialNumber
		    OCTET STRING,
		psOperatingTime
		    INTEGER,
        psDirectAccess OBJECT-TYPE
            OCTET STRING
}

--integrated in system.sysDesc
--psFirmwareVersion OBJECT-TYPE
--    SYNTAX  DisplayString
--    ACCESS  read-only
--    STATUS  current
--    DESCRIPTION
--            "The firmware version of the power supply main CPU."
--    ::= { powersupply 1 }

psSerialNumber OBJECT-TYPE
    SYNTAX  DisplayString
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The serial number of the power supply."
    ::= { powersupply 2 }

psOperatingTime OBJECT-TYPE
    SYNTAX  INTEGER
    UNITS   "s"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The time in seconds for how long the power supply was switched on."
    ::= { powersupply 3 }

psDirectAccess OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE (1..14))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "Direct data transfer to the UEP6000 power supply.
             A read access returns nothing, a write access returns the
             response of the power supply.
            "
    ::= { powersupply 1024 }

-------------------------------------------------------------------------------
-- fantray
-------------------------------------------------------------------------------
Fantray ::= SEQUENCE {
        fanFirmwareVersion
            DisplayString,
        fanSerialNumber
		    OCTET STRING,
		fanOperatingTime
		    INTEGER,
		fanAirTemperature
		    INTEGER,
		fanSwitchOffDelay
		    INTEGER,
		fanNominalSpeed
		    INTEGER,
		fanNumberOfFans
		    INTEGER,
        fanSpeedTable
		    FanSpeedTable
}

--integrated in system.sysDesc
--fanFirmwareVersion OBJECT-TYPE
--    SYNTAX  DisplayString
--    ACCESS  read-only
--    STATUS  current
--    DESCRIPTION
--            "The firmware version of the fan tray CPU."
--    ::= { fantray 1 }

fanSerialNumber OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..14))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The serial number of the fan tray."
    ::= { fantray 2 }

fanOperatingTime OBJECT-TYPE
    SYNTAX  INTEGER
    UNITS   "s"
    ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The time in seconds for how long the fan tray was switched on."
    ::= { fantray 3 }

fanAirTemperature OBJECT-TYPE
    SYNTAX  INTEGER
    UNITS   "C"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The temperature of the fan tray inlet air."
    ::= { fantray 4 }

fanSwitchOffDelay OBJECT-TYPE
    SYNTAX  INTEGER (0 .. 900)
    UNITS   "s"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The maximum time in seconds for which the fans will continue running
			 after the power supply has been switched off. This feature is used
			 to cool down the electronics after switching off.
			"
    ::= { fantray 5 }

fanNominalSpeed OBJECT-TYPE
-- CHECK    SYNTAX  INTEGER { (0) , (1200..3600) }
    SYNTAX  INTEGER (0..3600)
    UNITS   "RPM"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The nominal fan rotation speed (RPM, Revolutions Per Minute)
			 Value 0 does switch off the fans (only allowed if at least
			 one rack temperature sensor is present).
			 Values 1..1199 are not allowed"
    ::= { fantray 6 }

fanNumberOfFans OBJECT-TYPE
    SYNTAX  INTEGER ( 0..12 )
    UNITS   "Fans"
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
            "The number of installed fans"
    ::= { fantray 7 }


fanSpeedTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF fanSpeedEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
           "A list of fanSpeedEntries."
    ::= { fantray 8 }

fanSpeedEntry OBJECT-TYPE
    SYNTAX  fanSpeedEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A table row"
    INDEX   { fanNumber }
    ::= { fanSpeedTable 1 }

fanSpeedEntry ::=
    SEQUENCE {
        fanNumber
            INTEGER,
        fanSpeed
            INTEGER
}

fanNumber OBJECT-TYPE
    SYNTAX  INTEGER ( 1..12 )
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
            "A unique number for each fan."
    ::= { fanSpeedEntry 1 }

fanSpeed OBJECT-TYPE
    SYNTAX  INTEGER
    UNITS   "RPM"
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
            "The measured fan rotation speed (RPM, Revolutions Per Minute)"
    ::= { fanSpeedEntry 2 }





-------------------------------------------------------------------------------
-- rack
-------------------------------------------------------------------------------
-- this is reserved for futer items (BIN serial number, plug&play, ...)



-------------------------------------------------------------------------------
END